| CBS350
Especificações dos switches Gigabit Ethernet Cisco Business 350 Series
|
||||
|---|---|---|---|---|
| Desempenho | ||||
| Capacidade de comutação e taxa de encaminhamento | Modelo | Capacidade em milhões de pacotes por segundo (pacotes de 64 bytes) | Capacidade de comutação em gigabits por segundo | |
| CBS350-8T-E-2G | 14,88 mpps | 20,0 Gbps | ||
| CBS350-8P-2G | 14,88 mpps | 20,0 Gbps | ||
| CBS350-8P-E-2G | 14,88 mpps | 20,0 Gbps | ||
| CBS350-8FP-2G | 14,88 mpps | 20,0 Gbps | ||
| CBS350-8FP-E-2G | 14,88 mpps | 20,0 Gbps | ||
| CBS350-8S-E-2G | 14,88 mpps | 20,0 Gbps | ||
| CBS350-16T-2G | 26,78 mpps | 36,0 Gbps | ||
| CBS350-16T-E-2G | 26,78 mpps | 36,0 Gbps | ||
| CBS350-16P-2G | 26,78 mpps | 36,0 Gbps | ||
| CBS350-16P-E-2G | 26,78 mpps | 36,0 Gbps | ||
| CBS350-16FP-2G | 26,78 mpps | 36,0 Gbps | ||
| CBS350-24T-4G | 41,66 mpps | 56,0 Gbps | ||
| CBS350-24P-4G | 41,66 mpps | 56,0 Gbps | ||
| CBS350-24FP-4G | 41,66 mpps | 56,0 Gbps | ||
| CBS350-24S-4G | 41,66 mpps | 56,0 Gbps | ||
| CBS350-48T-4G | 77,38 mpps | 104,0 Gbps | ||
| CBS350-48P-4G | 77,38 mpps | 104,0 Gbps | ||
| CBS350-48FP-4G | 77,38 mpps | 104,0 Gbps | ||
| Comutação da camada 2 | ||||
| Spanning Tree Protocol (STP) | Suporte a spanning tree padrão 802.1d Convergência rápida usando 802.1w (Rapid Spanning Tree Protocol [RSTP]), ativado por padrão Várias instâncias de spanning tree usando 802.1s (MSTP); 8 instâncias são suportadas Per-VLAN Spanning Tree Plus (PVST+) e Rapid PVST+ (RPVST+); 126 instâncias são suportadas |
|||
| Agrupamento de portas/agregação de links | Suporte para IEEE 802.3ad Link Aggregation Control Protocol (LACP)
|
|||
| VLAN | Suporte para até 4.094 VLANs simultaneamente VLANs baseadas em porta e baseadas em tags 802.1Q; VLAN baseada em MAC; VLAN baseada em protocolo; Gerenciamento de VLAN baseado em sub-rede IP VLAN VLAN privada com porta promíscua, isolada e comunitária Private VLAN Edge (PVE), também conhecida como portas protegidas, com vários uplinks VLAN convidada, VLAN não autenticada Atribuição dinâmica de VLAN via servidor RADIUS junto com autenticação de cliente 802.1x CPE VLAN |
|||
| Voz VLAN | O tráfego de voz é atribuído automaticamente a uma VLAN específica de voz e tratado com níveis apropriados de QoS. Os recursos de voz automática oferecem implantação sem toque em toda a rede de terminais de voz e dispositivos de controle de chamadas | |||
| VLAN de TV Multicast | Multicast TV VLAN permite que uma única VLAN multicast seja compartilhada na rede enquanto os assinantes permanecem em VLANs separadas. Esse recurso também é conhecido como Multicast VLAN Registration (MVR) | |||
| Tradução de VLAN | Suporte para mapeamento um-para-um de VLAN. No VLAN One-to-One Mapping, em uma interface de borda, as VLANs do cliente (C-VLANs) são mapeadas para as VLANs do provedor de serviços (S-VLANs) e as tags originais da C-VLAN são substituídas pela S-VLAN especificada | |||
| Q em Q | As VLANs atravessam de forma transparente uma rede de provedor de serviços enquanto isolam o tráfego entre os clientes | |||
| Q-em-Q Seletivo | Selective Q-in-Q é um aprimoramento do recurso Q-in-Q básico e fornece, por interface de borda, vários mapeamentos de diferentes C-VLANs para separar S-VLANs Selective Q-in-Q também permite a configuração de Ethertype ( Tag Protocol Identifier [TPID]) da tag S-VLAN Layer 2 protocol tunneling over Q-in-Q também é suportado |
|||
| Protocolo de registro de VLAN genérico (GVRP) e Protocolo de registro de atributo genérico (GARP) | O Generic VLAN Registration Protocol (GVRP) e o Generic Attribute Registration Protocol (GARP) permitem a propagação automática e a configuração de VLANs em um domínio com ponte | |||
| Detecção de link unidirecional (UDLD) | O UDLD monitora a conexão física para detectar links unidirecionais causados por fiação incorreta ou falhas de cabo/porta para evitar loops de encaminhamento e bloqueio de tráfego em redes comutadas | |||
| Retransmissão do protocolo de configuração de host dinâmico (DHCP) na camada 2 | Retransmissão de tráfego DHCP para servidor DHCP em VLAN diferente; funciona com opção DHCP 82 | |||
| Espionagem IGMP (versões 1, 2 e 3) | O IGMP limita o tráfego multicast com uso intensivo de largura de banda apenas aos solicitantes; suporta grupos multicast 2K (multicasting específico da fonte também é suportado) | |||
| Consultador IGMP | O consultador IGMP é usado para suportar um domínio multicast da Camada 2 de switches snooping na ausência de um roteador multicast | |||
| bloqueio HOL | Prevenção de bloqueio Head-of-Line (HOL) | |||
| Detecção de loopback | A detecção de loopback fornece proteção contra loops transmitindo pacotes de protocolo de loop de portas nas quais a proteção de loop foi habilitada. Opera independentemente do STP | |||
| Roteamento da camada 3 | ||||
| Roteamento IPv4 | Roteamento Wire-speed de pacotes IPv4 Até 990 rotas estáticas e até 128 interfaces IP |
|||
| Roteamento IPv6 | Roteamento de velocidade de fio de pacotes IPv6 | |||
| Interface da camada 3 | Configuração da interface da Camada 3 na porta física, Link Aggregation (LAG), interface VLAN ou interface de loopback | |||
| Roteamento entre domínios sem classes (CIDR) | Suporte para roteamento entre domínios sem classe | |||
| RIP v2 | Suporte para Routing Information Protocol versão 2 para roteamento dinâmico | |||
| Roteamento baseado em políticas (PBR) | Controle de roteamento flexível para direcionar pacotes para diferentes próximos saltos com base em lista de controle de acesso (ACL) IPv4 ou IPv6 | |||
| Servidor DHCP | O switch funciona como um servidor DHCP IPv4 servindo endereços IP para vários pools/escopos DHCP Suporte para opções DHCP |
|||
| Retransmissão DHCP na camada 3 | Retransmissão de tráfego DHCP entre domínios IP | |||
| User Datagram Protocol (UDP) relé | Retransmissão de informações de transmissão em domínios da Camada 3 para descoberta de aplicativos ou retransmissão de pacotes Bootstrap Protocol (BOOTP)/DHCP | |||
| Empilhamento | ||||
| Empilhamento de hardware | Até 4 unidades em uma pilha. Até 192 portas gerenciadas como um único sistema com failover de hardware | |||
| Alta disponibilidade | Failover de pilha rápida oferece perda mínima de tráfego. Oferece suporte à agregação de links em várias unidades em uma pilha | |||
| Configuração/gerenciamento de empilhamento plug-and-play | Ativo/espera para controle resiliente da pilha Numeração automática Hot swap de unidades na pilha Opções de empilhamento de anel e cadeia, velocidade da porta de empilhamento automático, opções flexíveis de porta de empilhamento |
|||
| Interconexões de pilha de alta velocidade | Interfaces de fibra 10G de alta velocidade econômicas | |||
| Segurança | ||||
| Secure Sockets Layer (SSL) | Suporte SSL: criptografa todo o tráfego HTTPS, permitindo acesso altamente seguro à GUI de gerenciamento baseada em navegador no switch | |||
| Protocolo Secure Shell (SSH) | O SSH é um substituto seguro para o tráfego Telnet. Secure Copy Protocol (SCP) também usa SSH. SSH v1 e v2 são suportados | |||
| IEEE 802.1X (função do autenticador) | 802.1X: Autenticação e contabilidade do Serviço de Usuário de Discagem de Autenticação Remota (RADIUS), hash MD5; VLAN convidada; VLAN não autenticada, modo de host único/múltiplo e sessões únicas/múltiplas Suporta 802.1X baseado em tempo; atribuição de VLAN dinâmica |
|||
| Autenticação baseada na Web | A autenticação baseada na Web fornece controle de admissão de rede por meio do navegador da Web para qualquer dispositivo host e sistema operacional | |||
| STP Bridge Protocol Data Unit (BPDU) Guard | Um mecanismo de segurança para proteger a rede de configurações inválidas. Uma porta habilitada para BPDU Guard é desligada se uma mensagem BPDU for recebida nessa porta. Isso evita loops de topologia acidentais | |||
| STP Root Guard | Isso evita que os dispositivos de borda que não estão sob o controle do administrador da rede se tornem nós raiz do Spanning Tree Protocol | |||
| Proteção de loopback STP | Fornece proteção adicional contra loops de encaminhamento da Camada 2 (loops STP) | |||
| Espionagem DHCP | Filtra mensagens DHCP com endereços IP não registrados e/ou de interfaces inesperadas ou não confiáveis. Isso evita que dispositivos não autorizados se comportem como servidores DHCP. | |||
| IP Source Guard (IPSG) | Quando o IP Source Guard está ativado em uma porta, o switch filtra os pacotes IP recebidos da porta se os endereços IP de origem dos pacotes não tiverem sido configurados estaticamente ou aprendidos dinamicamente pela espionagem DHCP. Isso evita a falsificação de endereço IP. | |||
| Inspeção ARP Dinâmica (DAI) | O switch descarta pacotes ARP de uma porta se não houver vínculos IP/MAC estáticos ou dinâmicos ou se houver uma discrepância entre os endereços de origem ou destino no pacote ARP. Isso evita ataques man-in-the-middle. | |||
| IP/MAC/Port Binding (IPMB) | Os recursos anteriores (DHCP Snooping, IP Source Guard e Dynamic ARP Inspection) funcionam juntos para evitar ataques DOS na rede, aumentando assim a disponibilidade da rede | |||
| Tecnologia Núcleo Segura (SCT) | Garante que o switch receberá e processará o gerenciamento e o tráfego de protocolo, independentemente da quantidade de tráfego recebido | |||
| Dados confidenciais seguros (SSD) | Um mecanismo para gerenciar dados confidenciais (como senhas, chaves e assim por diante) com segurança no switch, preenchendo esses dados para outros dispositivos e autoconfiguração segura. O acesso para visualizar os dados confidenciais como texto simples ou criptografado é fornecido de acordo com o nível de acesso configurado pelo usuário e o método de acesso do usuário. | |||
| Sistemas confiáveis | Sistemas confiáveis fornecem uma base altamente segura para defesas em tempo de execução dos produtos Cisco (Proteção de espaço executável [X-Space], Randomização de layout de espaço de endereço [ASLR], Verificação de tamanho de objeto integrada [BOSC]) |
|||
| Privado VLANVários níveis de privilégio de usuário na CLI | A VLAN privada fornece segurança e isolamento entre as portas do switch, o que ajuda a garantir que os usuários não possam bisbilhotar o tráfego de outros usuários; suporta vários uplinks | |||
| Isolamento de camada 2 Private VLAN Edge (PVE) com comunidade VLAN | PVE (também conhecido como portas protegidas) fornece isolamento de Camada 2 entre dispositivos na mesma VLAN, suporta vários uplinks | |||
| segurança portuária | Capacidade de bloquear endereços MAC de origem em portas e limitar o número de endereços MAC aprendidos | |||
| RAIO/TACACS+ | Suporta autenticação RADIUS e TACACS. Alternar funções como cliente | |||
| contabilidade RADIUS | As funções de contabilização RADIUS permitem o envio de dados no início e no fim dos serviços, indicando a quantidade de recursos (como tempo, pacotes, bytes, etc.) utilizados durante a sessão | |||
| controle de tempestade | Broadcast, multicast e unicast desconhecido | |||
| Prevenção DoS | Prevenção de ataques de negação de serviço (DOS) | |||
| Múltiplos níveis de privilégio de usuário na CLI | Níveis de privilégio de nível 1, 7 e 15 | |||
| ACLs | Suporte para até 1.024 regras Drop ou limite de taxa com base no MAC de origem e destino, VLAN ID, endereço IPv4 ou IPv6, rótulo de fluxo IPv6, protocolo, porta, ponto de código de serviços diferenciados (DSCP)/precedência de IP, protocolo de controle de transmissão/datagrama do usuário Portas de origem e destino do protocolo (TCP/UDP), prioridade 802.1p, tipo Ethernet, pacotes ICMP (Internet Control Message Protocol), pacotes IGMP, sinalizador TCP; ACL pode ser aplicada nos lados de entrada e saída ACLs baseados em tempo suportados |
|||
| Qualidade de serviço | ||||
| Níveis de prioridade | 8 filas de hardware | |||
| Agendamento | Prioridade estrita e Round-Robin ponderado (WRR) | |||
| classe de serviço | Baseado em porto; baseado em prioridade de VLAN 802.1p; Precedência de IP IPv4/v6/Tipo de serviço (ToS)/baseado em DSCP; Serviços Diferenciados (DiffServ); ACLs de classificação e observação, atribuição de fila de QoS confiável com base em DSCP e classe de serviço (802.1p/CoS) |
|||
| Limitação de taxa | Policial de ingresso; modelagem de saída e controle de taxa; por VLAN, por porta e com base em fluxo; policiamento 2R3C | |||
| prevenção de congestionamento | Um algoritmo de prevenção de congestionamento TCP é necessário para minimizar e evitar a sincronização global de perda de TCP | |||
| Otimização de tráfego iSCSI | Um mecanismo para dar prioridade ao tráfego iSCSI sobre outros tipos de tráfego | |||
| Padrões | ||||
| Padrões | IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3ad Link Aggregation Control Protocol, IEEE 802.3z Gigabit Ethernet, IEEE 802.3ae 10 Gbit/s Ethernet sobre fibra para LAN, IEEE 802.3an 10GBase-T 10 Gbit/s Ethernet sobre cabo de par trançado de cobre, IEEE 802.3x Flow Control, IEEE 802.1D (STP, GARP e GVRP), IEEE 802.1Q/p VLAN, IEEE 802.1w Rapid STP, IEEE 802.1s Multiple STP, IEEE 802.1X Port Access Authentication, IEEE 802.3af, IEEE 802.3at, IEEE 802.1AB Link Layer Discovery Protocol, IEEE 802.3az Energy Efficient Ethernet, RFC 768, RFC 783, RFC 791, RFC 792, RFC 793 , RFC 813, RFC 826, RFC 879, RFC 896, RFC 854, RFC 855, RFC 856, RFC 858, RFC 894, RFC 919, RFC 920, RFC 922, RFC 950, RFC 951, RFC 1042, RFC 1071, RFC 1123, RFC 1141, RFC 1155, RFC 1157, RFC 1213, RFC 1215, RFC 1286,RFC 1350, RFC 1442, RFC 1451, RFC 1493, RFC 1533, RFC 1541, RFC 1542, RFC 1573, RFC 1624, RFC 1643, RFC 1700, RFC 1757, RFC 1867, RFC 1907, RFC 2011, RFC 2011, RFC 2012 , RFC 2030, RFC 2131, RFC 2132, RFC 2233, RFC 2576, RFC 2616, RFC 2618, RFC 2665, RFC 2666, RFC 2674, RFC 2737, RFC 2819, RFC 2863, RFC 3164, RFC 3176, RFC 3141 3412, RFC 3413, RFC 3414, RFC 3415, RFC 3416, RFC 4330 | |||
| IPv6 | ||||
| IPv6 | modo de host IPv6; IPv6 sobre Ethernet; Pilha dupla IPv6/IPv4 vizinho IPv6 e descoberta de roteador (ND); Autoconfiguração de endereços IPv6 sem estado; Path Maximum Transmission Unit (MTU) descoberta Detecção de Endereço Duplicado (DAD); ICMP versão 6 DHCPv6 stateful client IPv6 sobre rede IPv4 com suporte ao Intrasite Automatic Tunnel Addressing Protocol (ISATAP) certificado USGv6 e IPv6 Gold Logo |
|||
| IPv6 QoS | Priorizar pacotes IPv6 no hardware | |||
| IPv6 ACL | Eliminar ou limitar a taxa de pacotes IPv6 no hardware | |||
| Segurança de primeiro salto IPv6 | Proteção RA ND Inspeção Proteção DHCPv6 Tabela de ligação de vizinho (entradas de espionagem e estáticas) Verificação de integridade de ligação de vizinho |
|||
| Espionagem de descoberta de ouvinte multicast (MLD v1/2) | Entregue pacotes multicast IPv6 apenas para os receptores necessários | |||
| aplicações IPv6 | Web/SSL, servidor Telnet/SSH, ping, traceroute, Simple Network Time Protocol (SNTP), Trivial File Transfer Protocol (TFTP), SNMP, RADIUS, syslog, cliente DNS (Domain Name System), cliente Telnet, cliente DHCP, DHCP Autoconfig, IPv6 DHCP Relay, Terminal Access Controller Access Control System Plus (TACACS+) | |||
| RFCs IPv6 suportados | RFC 4443 (que torna obsoleto o RFC 2463): ICMPv6 RFC 4291 (que torna obsoleto o RFC 3513): Arquitetura de endereço IPv6 RFC 4291: Arquitetura de endereçamento IPv6 RFC 2460: Especificação IPv6 RFC 4861 (que torna obsoleto o RFC 2461): Neighbor Discovery for IPv6 RFC 4862 (que torna obsoleto o RFC 2461): obsoleto RFC 2462): IPv6 Stateless Address Autoconfiguration RFC 1981: Path MTU Discovery RFC 4007: IPv6 Scoped Address Architecture RFC 3484: Default address selection engine RFC 5214 (que torna obsoleto RFC 4214): ISATAP tunneling RFC 4293: Management Information Base (MIB) IPv6 : Convenções Textuais e Grupo Geral RFC 3595: Convenções textuais para rótulo de fluxo IPv6 |
|||
| Gerenciamento | ||||
| Painel de negócios da Cisco | Suporte para sonda incorporada para Cisco Business Dashboard em execução no switch. Elimina a necessidade de configurar um hardware separado ou uma máquina virtual para o Cisco Business Dashboard Probe no local. | |||
| Aplicativo móvel Cisco Business | Aplicativo móvel para produtos Cisco Business Switch e Wireless. Ajuda a configurar uma rede local em minutos e fornece gerenciamento fácil ao seu alcance. | |||
| Agente Cisco Network Plug and Play (PnP) | A solução Cisco Network Plug and Play oferece uma oferta simples, segura, unificada e integrada para facilitar a implantação de novos dispositivos em filiais ou campus ou para provisionar atualizações para uma rede existente. A solução fornece uma abordagem unificada para fornecer roteadores, switches e dispositivos sem fio Cisco com uma experiência de implantação quase sem toque. Suporta Cisco PnP Connect |
|||
| interface do usuário da web | Utilitário de configuração de switch integrado para fácil configuração de dispositivo baseada em navegador (HTTP/HTTPS). Suporta configuração, assistentes, painel do sistema, manutenção do sistema e monitoramento Modo básico e avançado para máxima eficiência operacional |
|||
| SNMP | SNMP versões 1, 2c e 3 com suporte para traps e SNMP v3 User-based Security Model (USM) | |||
| MIBs padrão | lldp-MIB lldpextdot1-MIB lldpextdot3-MIB lldpextmed-MIB rfc2674-MIB rfc2575-MIB rfc2573-MIB rfc2233-MIB rfc2013-MIB rfc2012-MIB rfc2011-MIB RFC-1212 RFC-1215 SNMPv2-CONF SNMPv2-TC p-bridge-MIB q-bridge-MIB rfc1389-MIB rfc1493-MIB rfc1611-MIB rfc1612-MIB rfc1850-MIB rfc1907-MIB rfc2571-MIB rfc2572-MIB rfc2574-MIB rfc2576-MIB rfc2613-MIB rfc2665-MIB |
rfc2668-MIB rfc2737-MIB rfc2925-MIB rfc3621-MIB rfc4668-MIB rfc4670-MIB tronco-MIB túnel-MIB udp-MIB draft-ietf-bridge-8021x-MIB draft-ietf-bridge-rstpmib-04-MIB draft-ietf -hubmib-etherif-mib-v3-00-MIB draft-ietf-syslog-device-MIB ianaaddrfamnumbers-MIB ianaifty-MIB ianaprot-MIB inet-address-MIB ip-forward-MIB ip-MIB RFC1155-SMI RFC1213-MIB SNMPv2-MIB SNMPv2-SMI SNMPv2-TM RMON-MIB rfc1724-MIB dcb-raj-DCBX-MIB-1108-MIB rfc1213-MIB rfc1757-MIB |
||
| MIBs privados | CISCOSB-lldp-MIB CISCOSB-brgmulticast-MIB CISCOSB-bridgemibobjects-MIB CISCOSB-bonjour-MIB CISCOSB-dhcpcl-MIB CISCOSB -MIB CISCOSB-wrandomtaildrop-MIB CISCOSB-traceroute-MIB CISCOSB-telnet-MIB CISCOSB-stormctrl-MIB CISCOSBssh- MIB CISCOSB-socket-MIB CISCOSB-sntp-MIB CISCOSB-smon-MIB CISCOSB-phy-MIB CISCOSB-multisessionterminal-MIB CISCOSB-mri-MIB CISCOSB-jumboframes-MIB CISCOSB- gvrp-MIB CISCOSB-endofmib-MIB CISCOSB-dot1x-MIB CISCOSB-deviceparams-MIB CISCOSB-cli-MIB CISCOSB-cdb-MIB CISCOSB-brgmacswitch-MIB CISCOSB-3sw2swtables-MIB CISCOSB-smartPorts-MIB CISCOSB-tbi-MIB CISCOSB-macbaseprio-MIB CISCOSB-env_mib-MIB CISCOSB-policy-MIB CISCOSB-sensor-MIB CISCOSB-aaa-MIB CISCOSB-application-MIB CISCOSB-bridgesecurity-MIB CISCOSB-copy-MIB CISCOSB-CpuCounters-MIB CISCOSB-Custom1BonjourService-MIB CISCOSB-dhcp-MIB CISCOSB-dlf-MIB CISCOSB-dnscl-MIB CISCOSB-embweb-MIB CISCOSB-fft-MIB CISCOSB-file-MIB CISCOSB-greeneth-MIB CISCOSB-interfaces-MIB CISCOSB-interfaces_recovery-MIB |
CISCOSB-ip-MIB CISCOSB-iprouter-MIB CISCOSB-ipv6-MIB CISCOSB-mnginf-MIB CISCOSB-lcli-MIB CISCOSB-localização-MIB CISCOSB-mcmngr-MIB CISCOSB-mng-MIB CISCOSB-fisdescrição-MIB CISCOSB-PoE-MIB CISCOSB-protectedport-MIB CISCOSB-rmon-MIB CISCOSB-rs232-MIB CISCOSB-SecuritySuite-MIB CISCOSB-snmp-MIB CISCOSB-specialbpdu-MIB CISCOSB -banner-MIB CISCOSB- syslog-MIB CISCOSB-TcpSession-MIB CISCOSB-traps-MIB CISCOSB-trunk-MIB CISCOSB-tuning-MIB CISCOSB-tunnel-MIB CISCOSB-udp-MIB CISCOSB-vlan-MIB CISCOSB -ipstdacl-MIB CISCOSB-eee-MIB CISCOSB-ssl-MIB CISCOSB-qosclimib-MIB CISCOSB-digitalkeymanage-MIB CISCOSB-tbp-MIB CISCOSMB-MIB CISCOSB-secsd-MIB CISCOSB-draft-ietf-entmib-sensor-MIB CISCOSB-draft-ietf-syslog-device-MIB CISCOSB-rfc2925-MIB CISCO-SMI-MIB CISCOSB-DebugCapabilities-MIB CISCOSB-CDP-MIB CISCOSB-vlanVoice-MIB CISCOSB-EVENTS-MIB CISCOSB-sysmng-MIB CISCOSB -sct-MIB CISCO -TC-MIB CISCO- VTP-MIB CISCO-CDP-MIB |
||
| Monitoramento remoto (RMON) | O agente de software RMON incorporado suporta 4 grupos RMON (histórico, estatísticas, alarmes e eventos) para gerenciamento, monitoramento e análise de tráfego aprimorados | |||
| Pilha dupla IPv4 e IPv6 | Coexistência de ambas as pilhas de protocolo para facilitar a migração | |||
| Atualização de firmware | Atualização do navegador da Web (HTTP/HTTPS) e TFTP e atualização sobre SCP executando sobre SSH Imagens duplas para atualizações de firmware resilientes |
|||
| Espelhamento de porta | O tráfego em uma porta pode ser espelhado em outra porta para análise com um analisador de rede ou sonda RMON. Até 4 portas de origem podem ser espelhadas em uma porta de destino | |||
| Espelhamento de VLAN | O tráfego de uma VLAN pode ser espelhado em uma porta para análise com um analisador de rede ou sonda RMON. Até 4 VLANs de origem podem ser espelhadas em uma porta de destino | |||
| Dynamic Host Configuration Protocol (DHCP) (opções 12, 66, 67, 129 e 150) | As opções de DHCP facilitam um controle mais rígido a partir de um ponto central (servidor DHCP), para obter endereço IP, autoconfiguração (com download do arquivo de configuração), DHCP Relay e nome do host | |||
| Cópia Segura (SCP) | Transfere arquivos com segurança de e para o switch | |||
| Autoconfiguração com download de arquivo SCP | Permite implantação em massa com proteção de dados confidenciais | |||
| Configurações editáveis em texto | Os arquivos de configuração podem ser editados com um editor de texto e baixados para outro switch, facilitando a implantação em massa | |||
| Smartports | Configuração simplificada de QoS e recursos de segurança | |||
| Auto Smartports | Aplica automaticamente a inteligência fornecida por meio das funções Smartports à porta com base nos dispositivos descobertos por meio do Cisco Discovery Protocol ou LLDP-MED. Isso facilita implantações sem intervenção. | |||
| Visualização de texto Interface de linha de comando (CLI) | CLI programável. Uma CLI completa, bem como uma CLI baseada em menu, são suportadas. Os níveis de privilégio de usuário 1, 7 e 15 são compatíveis com a CLI. | |||
| Localização | Localização de GUI e documentação em vários idiomas | |||
| banner de login | Múltiplos banners configuráveis para web, bem como CLI | |||
| outra gestão | Traceroute; gerenciamento de IP único; HTTP/HTTPS; RAIO; espelhamento de porta; Atualização de TFTP; cliente DHCP; Protocolo Simples de Tempo de Rede (SNTP); diagnóstico de cabos; Ping; log do sistema; Cliente Telnet (suporte seguro SSH); configurações automáticas de tempo da estação de gerenciamento | |||
| Verde (Eficiência de Energia) | ||||
| Detecção de energia | Desliga automaticamente a energia na porta RJ-45 ao detectar link inativo. O modo ativo é retomado sem perda de nenhum pacote quando o switch detecta que o link está ativo | |||
| Detecção de comprimento de cabo | Ajusta a intensidade do sinal com base no comprimento do cabo. Reduz o consumo de energia para cabos mais curtos | |||
| Compatível com EEE (802.3az) | Suporta IEEE 802.3az em todas as portas Gigabit Ethernet de cobre | |||
| Desativar LEDs de porta | Os LEDs podem ser desligados manualmente para economizar energia | |||
| Operação de porta baseada em tempo | Link para cima ou para baixo com base na programação definida pelo usuário (quando a porta estiver administrativamente ativa) | |||
| PoE baseado em tempo | A energia PoE pode ser ligada ou desligada com base na programação definida pelo usuário para economizar energia | |||
| Em geral | ||||
| Quadros jumbo | Tamanhos de quadro de até 9K bytes. O MTU padrão é 2K bytes | |||
| tabela MAC | 16K endereços | |||
| Descoberta | ||||
| Bom dia | O switch se anuncia usando o protocolo Bonjour | |||
| Link Layer Discovery Protocol (LLDP) (802.1ab) com extensões LLDP-MED | O Link Layer Discovery Protocol (LLDP) permite que o switch anuncie sua identificação, configuração e recursos para dispositivos vizinhos que armazenam os dados em um MIB. LLDP-MED é um aprimoramento do LLDP que adiciona as extensões necessárias para telefones IP | |||
| Protocolo de Descoberta Cisco | O switch se anuncia usando o Cisco Discovery Protocol. Também aprende o dispositivo conectado e suas características usando o Cisco Discovery Protocol | |||
| Power over Ethernet (PoE) | ||||
| 802.3af PoE, 802.3at PoE+ ou 60W PoE fornecido pelas portas RJ-45 dentro dos orçamentos de energia listados | Os seguintes switches suportam 802.3at PoE+, 802.3af e Cisco pré-padrão (legado) PoE. O PoE de 60 W também é suportado em portas de rede RJ-45 selecionadas em modelos selecionados. A potência total disponível para PoE por switch é a seguinte: | |||
| Modelo | Energia dedicada ao PoE | Número de portas que suportam PoE | ||
| CBS350-8P-2G | 67 W | 8 | ||
| CBS350-8P-E-2G | 60W | 8 | ||
| CBS350-8FP-2G | 120W | 8 | ||
| CBS350-8FP-E-2G | 120W | 8 | ||
| CBS350-16P-2G | 120W | 16 | ||
| CBS350-16P-E-2G | 120W | 16 | ||
| CBS350-16FP-2G | 120W | 16 | ||
| 350-24P-4G | 240W | 24 | ||
| CBS350-24FP-4G | 195W | 24 | ||
| 350-48P-4G | 370 W | 48 | ||
| CBS350-48FP-4G | 370 W | 48 | ||
| Consumo de energia (pior caso) | Modelo | Consumo de energia do sistema | Consumo de energia (com PoE) | Dissipação de calor (BTU/h) |
| 350-8T-E-2G | 110V=12,55W 220V=12,56W |
N / D | 42,86 | |
| 350-8P-2G | 110V=17,35W 220V=17,95W |
110V=83,17W 220V=82,63W |
283,79 | |
| 350-8P-E-2G | 110V=13,84W 220V=14,31W |
110V=80,79W 220V=80,86W |
275,91 | |
| 350-8FP-2G | 110V=17,29W 220V=17,88W |
110V=148,12W 220V=146,36W |
505.41 | |
| 350-8FP-E-2G | 110V=17,07W 220V=16,68W |
110V=147,48W 220V=145,26W |
503.22 | |
| 350-8S-E-2G | 110V=11,1W 220V=11,9W |
N / D | 40,6 | |
| 350-16T-2G | 110V=18,63W 220V=18,37W |
N / D | 64,46 | |
| 350-16T-E-2G | 110V=19,63W 220V=19,32W |
N / D | 65,92 | |
| 350-16P-2G | 110V=24,51W 220V=25,01W |
110V=156,4W 220V=154,5W |
536,39 | |
| 350-16P-E-2G | 110V=23,65W 220V=23,68W |
110V=150,1W 220V=148,8W |
512.16 | |
| 350-16FP-2G | 110V=27,53W 220V=26,68W |
110V=284W 220V=279,8W |
971,78 | |
| 350-24T-4G | 110V=25,91W 220V=25,63W |
N / D | 89.13 | |
| 350-24P-4G | 110V=34,42W 220V=33,09W |
110V=239,7W 220V=236,4W |
820,62 | |
| 350-24FP-4G | 110V=46,60W 220V=46,35W |
110V=449,7W 220V=438,3W |
1.537,17 | |
| 350-24S-4G | 110V=32,0W 220V=34,3W |
N / D | 117,0 | |
| 350-48T-4G | 110V=48,27W 220V=48,64W |
N / D | 165,96 | |
| 350-48P-4G | 110V=60,77W 220V=59,73W |
110V=451,95W 220V=445,85W |
1.542,12 | |
| 350-48FP-4G | 110V=73,79W 220V=74,03W |
110V=886,42W 220V=859,50W |
3.024,59 | |
| portas | Nome do modelo | Total de portas do sistema | portas RJ-45 | Portas combinadas (RJ-45 + SFP) |
| CBS350-8T-E-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Combinação Gigabit Ethernet | |
| CBS350-8P-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Combinação Gigabit Ethernet | |
| CBS350-8P-E-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Combinação Gigabit Ethernet | |
| CBS350-8FP-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Combinação Gigabit Ethernet | |
| CBS350-8FP-E-2G | 10 x Gigabit Ethernet | 8 x Gigabit Ethernet | 2 x Combinação Gigabit Ethernet | |
| CBS350-8S-E-2G | 10 x Gigabit Ethernet | 8 Slots Gigabit SFP | 2 x Combinação Gigabit Ethernet | |
| CBS350-16T-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2x SFP | |
| CBS350-16T-E-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2x SFP | |
| CBS350-16P-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2x SFP | |
| CBS350-16P-E-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2x SFP | |
| CBS350-16FP-2G | 18 x Gigabit Ethernet | 16 x Gigabit Ethernet | 2x SFP | |
| CBS350-24T-4G | 28 x Gigabit Ethernet | 24 x Gigabit Ethernet | 4 x SFP | |
| CBS350-24P-4G | 28 x Gigabit Ethernet | 24 x Gigabit Ethernet | 4 x SFP | |
| CBS350-24FP-4G | 28 x Gigabit Ethernet | 24 x Gigabit Ethernet | 4 x SFP | |
| CBS350-24S-4G | 28 x Gigabit Ethernet | 24 Slots Gigabit SFP | 4 x SFP | |
| CBS350-48T-4G | 52 x Gigabit Ethernet | 48 x Gigabit Ethernet | 4 x SFP | |
| CBS350-48P-4G | 52 x Gigabit Ethernet | 48 x Gigabit Ethernet | 4 x SFP | |
| CBS350-48FP-4G | 52 x Gigabit Ethernet | 48 x Gigabit Ethernet | 4 x SFP | |
| Porta do console | Porta de console mini USB tipo B/RJ45 padrão da Cisco: CBS350-8T-E-2G, CBS350-8P-2G, CBS350-8P-E-2G, CBS350-8FP-2G, CBS350-8FP-E-2G, CBS350- 16T-2G, CBS350-16T-E-2G, CBS350-16P-2G, CBS350-16P-E-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G Porta de console RJ45 padrão Cisco: CBS350-8S-E-2G, CBS350-24S-4G |
|||
| entrada USB | Slot USB tipo A no painel frontal do switch para fácil gerenciamento de arquivos e imagens | |||
| Botões | Botão de reset | |||
| Tipo de cabeamento | Par trançado não blindado (UTP) Categoria 5e ou melhor para 1000BASE-T | |||
| LEDs | Sistema, Link/Act, PoE, Velocidade | |||
| Clarão | 256 MB | |||
| CPU | 800 MHz ARM | |||
| DRAM | 512 MB | |||
| buffer de pacotes | Todos os números são agregados em todas as portas porque os buffers são compartilhados dinamicamente: | |||
| Nome do modelo | buffer de pacotes | |||
| CBS350-8T-E-2G | 1,5 MB | |||
| CBS350-8P-2G | 1,5 MB | |||
| CBS350-8P-E-2G | 1,5 MB | |||
| CBS350-8FP-2G | 1,5 MB | |||
| CBS350-8FP-E-2G | 1,5 MB | |||
| CBS350-8S-E-2G | 1,5 MB | |||
| CBS350-16T-2G | 1,5 MB | |||
| CBS350-16T-E-2G | 1,5 MB | |||
| CBS350-16P-2G | 1,5 MB | |||
| CBS350-16P-E-2G | 1,5 MB | |||
| CBS350-16FP-2G | 1,5 MB | |||
| CBS350-24T-4G | 1,5 MB | |||
| CBS350-24P-4G | 1,5 MB | |||
| CBS350-24FP-4G | 1,5 MB | |||
| CBS350-24S-4G | 1,5 MB | |||
| CBS350-48T-4G | 3 MB | |||
| CBS350-48P-4G | 3 MB | |||
| CBS350-48FP-4G | 3 MB | |||
| Módulos SFP/SFP+ suportados | SKU | meios de comunicação | Velocidade | Distância máxima |
| MGBSX1 | fibra multimodo | 1000 Mbps | 500m | |
| MGBLH1 | Fibra monomodo | 1000 Mbps | 40 km | |
| MGBLX1 | Fibra monomodo | 1000 Mbps | 10 km | |
| MGBT1 | UTP cat 5e | 1000 Mbps | 100m | |
| GLC-SX-MMD | fibra multimodo | 1000 Mbps | 550 m | |
| GLC-LH-SMD | Fibra monomodo | 1000 Mbps | 10 km | |
| GLC-BX-U | Fibra monomodo | 1000 Mbps | 10 km | |
| GLC-BX-D | Fibra monomodo | 1000 Mbps | 10 km | |
| GLC-TE | UTP cat 5e | 1000 Mbps | 100m | |
| SFP-H10GB-CU1M | cobre coaxial | 10 GB | 1m | |
| SFP-H10GB-CU3M | cobre coaxial | 10 GB | 3m | |
| SFP-H10GB-CU5M | cobre coaxial | 10 GB | 5m | |
| SFP-10G-SR | fibra multimodo | 10 GB | 26 m – 400 m | |
| SFP-10G-LR | Fibra monomodo | 10 GB | 10 km | |
| SFP-10G-SR-S | fibra multimodo | 10 GB | 26 m – 400 m | |
| SFP-10G-LR-S | Fibra monomodo | 10 GB | 10 km | |
| Ambiental | ||||
| Dimensões da unidade (L x P x A) |
Nome do modelo | Dimensões da unidade | ||
| CBS350-8T-E-2G | 268 x 185 x 44 mm (10,56 x 7,28 x 1,73 pol.) | |||
| CBS350-8P-2G | 268 x 272 x 44 mm (10,56 x 10,71 x 1,73 pol.) | |||
| CBS350-8P-E-2G | 268 x 185 x 44 mm (10,56 x 7,28 x 1,73 pol.) | |||
| CBS350-8FP-2G | 268 x 272 x 44 mm (10,56 x 10,71 x 1,73 pol.) | |||
| CBS350-8FP-E-2G | 268 x 185 x 44 mm (10,56 x 7,28 x 1,73 pol.) | |||
| CBS350-8S-E-2G | 280 x 170 x 44 mm (11,0 x 6,69 x 1,73 pol.) | |||
| CBS350-16T-2G | 268 x 272 x 44 mm (10,56 x 10,69 x 1,73 pol.) | |||
| CBS350-16T-E-2G | 268 x 210 x 44 mm (10,56 x 8,26 x 1,73 pol.) | |||
| CBS350-16P-2G | 268 x 297 x 44 mm (10,56 x 11,69 x 1,73 pol.) | |||
| CBS350-16P-E-2G | 268 x 210 x 44 mm (10,56 x 8,26 x 1,73 pol.) | |||
| CBS350-16FP-2G | 268 x 308 x 44 mm (10,56 x 12,14 x 1,73 pol.) | |||
| CBS350-24T-4G | 445 x 240 x 44 mm (17,5 x 9,45 x 1,73 pol.) | |||
| CBS350-24P-4G | 445 x 299 x 44 mm (17,5 x 11,77 x 1,73 pol.) | |||
| CBS350-24FP-4G | 445 x 345 x 44 mm (17,5 x 13,59 x 1,73 pol.) | |||
| CBS350-24S-4G | 440 x 203 x 44 mm (17,3 x 7,99 x 1,73 pol.) | |||
| CBS350-48T-4G | 445 x 288 x 44 mm (17,5 x 11,33 x 1,73 pol.) | |||
| CBS350-48P-4G | 445 x 350 x 44 mm (17,5 x 13,78 x 1,73 pol.) | |||
| CBS350-48FP-4G | 445 x 350 x 44 mm (17,5 x 13,78 x 1,73 pol.) | |||
| Unidade de peso | Nome do modelo | Unidade de peso | ||
| CBS350-8T-E-2G | 1,39 kg (3,06 libras) | |||
| CBS350-8P-2G | 2,59 kg (5,71 lb) | |||
| CBS350-8P-E-2G | 1,53 kg (3,37 lb) | |||
| CBS350-8FP-2G | 2,59 kg (5,71 lb) | |||
| CBS350-8FP-E-2G | 1,53 kg (3,37 lb) | |||
| CBS350-8S-E-2G | 1,0 kg (2,20 lb) | |||
| CBS350-16T-2G | 1,78 kg (3,92 libras) | |||
| CBS350-16T-E-2G | 1,42 kg (3,13 libras) | |||
| CBS350-16P-2G | 2,38 kg (5,25 lb) | |||
| CBS350-16P-E-2G | 1,42 kg (3,13 libras) | |||
| CBS350-16FP-2G | 2,49 kg (5,49 lb) | |||
| CBS350-24T-4G | 2,63 kg (5,80 lb) | |||
| CBS350-24P-4G | 3,53 kg (7,78 lb) | |||
| CBS350-24FP-4G | 4,6 kg (10,14 libras) | |||
| CBS350-24S-4G | 2,7 kg (5,95 libras) | |||
| CBS350-48T-4G | 3,95 kg (8,71 libras) | |||
| CBS350-48P-4G | 5,43 kg (11,97 libras) | |||
| CBS350-48FP-4G | 5,82 kg (12,83 libras) | |||
| Poder | 100-240 V 50-60 Hz, interno, universal: CBS350-8P-2G, CBS350-8FP-2G, CBS350-16T-2G, CBS350-16P-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350- 24P-4G, CBS350-24FP-4G, CBS350-24S-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G 100-240V 50-60 Hz, externo: CBS350-8T-E-2G , CBS350-8P-E-2G, CBS350-8FP-E-2G, CBS350-8S-E-2G, CBS350-16T-E-2G, CBS350-16P-E-2G |
|||
| Certificação | UL (UL 60950), CSA (CSA 22.2), marca CE, FCC Parte 15 (CFR 47) Classe A | |||
| Temperatura de operação | 23° a 122°F (-5° a 50°C) CBS350-8T-E-2G, CBS350-8P-2G, CBS350-8P-E-2G, CBS350-8FP-2G, CBS350-8FP-E-2G , CBS350-16T-2G, CBS350-16T-E-2G, CBS350-16P-2G, CBS350-16P-E-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP -4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G 32° a 122°F (0° a 50°C) CBS350-8S-E-2G, CBS350-24S-4G |
|||
| Temperatura de armazenamento | -13° a 158°F (-25° a 70°C) | |||
| Umidade operacional | 10% a 90%, relativo, sem condensação | |||
| Umidade de armazenamento | 10% a 90%, relativo, sem condensação | |||
| Ruído acústico e tempo médio entre falhas (MTBF) | Nome do modelo CBS | Ventilador (número) | ruído acústico | MTBF a 25°C (horas) |
| 350-8T-E-2G | sem ventoinha | N / D | 2.171.669 | |
| 350-8P-2G | sem ventoinha | N / D | 1.786.412 | |
| 350-8P-E-2G | sem ventoinha | N / D | 1.706.649 | |
| 350-8FP-2G | sem ventoinha | N / D | 1.786.412 | |
| 350-8FP-E-2G | sem ventoinha | N / D | 1.706.649 | |
| 350-8S-E-2G | sem ventoinha | N / D | 2.242.229 | |
| 350-16T-2G | sem ventoinha | N / D | 2.165.105 | |
| 350-16T-E-2G | sem ventoinha | N / D | 2.165.105 | |
| 350-16P-2G | sem ventoinha | N / D | 706.983 | |
| 350-16P-E-2G | sem ventoinha | N / D | 706.983 | |
| 350-16FP-2G | sem ventoinha | N / D | 706.983 | |
| 350-24T-4G | sem ventoinha | N / D | 2.026.793 | |
| 350-24P-4G | sem ventoinha | N / D | 698.220 | |
| 350-24FP-4G | 1 | 25°C: 34,8 dBA | 698.220 | |
| 350-24S-4G | sem ventoinha | N / D | 258.544 | |
| 350-48T-4G | 1 | 25°C: 29,7 dBA | 1.452.667 | |
| 350-48P-4G | 1 | 25°C: 37,3 dBA | 856.329 | |
| 350-48FP-4G | 1 | 25°C: 48,7 dBA | 856.301 | |
| garantia |
Tempo de vida limitado
|
|||
| Conteúdo do pacote | ||||
|
| Requerimentos mínimos | ||||
|