CBS350

Especificações dos switches Gigabit Ethernet Cisco Business 350 Series

 

 

CBS350 Series Managed Switches

Desempenho
Capacidade de comutação e taxa de encaminhamentoModeloCapacidade em milhões de pacotes por segundo (pacotes de 64 bytes)Capacidade de comutação em gigabits por segundo
CBS350-8T-E-2G14,88 mpps20,0 Gbps
CBS350-8P-2G14,88 mpps20,0 Gbps
CBS350-8P-E-2G14,88 mpps20,0 Gbps
CBS350-8FP-2G14,88 mpps20,0 Gbps
CBS350-8FP-E-2G14,88 mpps20,0 Gbps
CBS350-8S-E-2G14,88 mpps20,0 Gbps
CBS350-16T-2G26,78 mpps36,0 Gbps
CBS350-16T-E-2G26,78 mpps36,0 Gbps
CBS350-16P-2G26,78 mpps36,0 Gbps
CBS350-16P-E-2G26,78 mpps36,0 Gbps
CBS350-16FP-2G26,78 mpps36,0 Gbps
CBS350-24T-4G41,66 mpps56,0 Gbps
CBS350-24P-4G41,66 mpps56,0 Gbps
CBS350-24FP-4G41,66 mpps56,0 Gbps
CBS350-24S-4G41,66 mpps56,0 Gbps
CBS350-48T-4G77,38 mpps104,0 Gbps
CBS350-48P-4G77,38 mpps104,0 Gbps
CBS350-48FP-4G77,38 mpps104,0 Gbps
Comutação da camada 2
Spanning Tree Protocol (STP)Suporte a spanning tree padrão 802.1d
Convergência rápida usando 802.1w (Rapid Spanning Tree Protocol [RSTP]), ativado por padrão
Várias instâncias de spanning tree usando 802.1s (MSTP); 8 instâncias são suportadas
Per-VLAN Spanning Tree Plus (PVST+) e Rapid PVST+ (RPVST+); 126 instâncias são suportadas
Agrupamento de portas/agregação de linksSuporte para IEEE 802.3ad Link Aggregation Control Protocol (LACP)

  • Até 8 grupos
  • Até 8 portas por grupo com 16 portas candidatas para cada (dinâmico) 802.3ad Link Aggregation Group (LAG)
VLANSuporte para até 4.094 VLANs simultaneamente
VLANs baseadas em porta e baseadas em tags 802.1Q; VLAN baseada em MAC; VLAN baseada em protocolo;
Gerenciamento de VLAN baseado em sub-rede IP VLAN
VLAN privada com porta promíscua, isolada e comunitária
Private VLAN Edge (PVE), também conhecida como portas protegidas, com vários uplinks
VLAN convidada, VLAN não autenticada
Atribuição dinâmica de VLAN via servidor RADIUS junto com autenticação de cliente 802.1x
CPE VLAN
Voz VLANO tráfego de voz é atribuído automaticamente a uma VLAN específica de voz e tratado com níveis apropriados de QoS. Os recursos de voz automática oferecem implantação sem toque em toda a rede de terminais de voz e dispositivos de controle de chamadas
VLAN de TV MulticastMulticast TV VLAN permite que uma única VLAN multicast seja compartilhada na rede enquanto os assinantes permanecem em VLANs separadas. Esse recurso também é conhecido como Multicast VLAN Registration (MVR)
Tradução de VLANSuporte para mapeamento um-para-um de VLAN. No VLAN One-to-One Mapping, em uma interface de borda, as VLANs do cliente (C-VLANs) são mapeadas para as VLANs do provedor de serviços (S-VLANs) e as tags originais da C-VLAN são substituídas pela S-VLAN especificada
Q em QAs VLANs atravessam de forma transparente uma rede de provedor de serviços enquanto isolam o tráfego entre os clientes
Q-em-Q SeletivoSelective Q-in-Q é um aprimoramento do recurso Q-in-Q básico e fornece, por interface de borda, vários mapeamentos de diferentes C-VLANs para separar S-VLANs Selective Q-in-Q também permite a configuração de Ethertype (
Tag Protocol Identifier [TPID]) da tag S-VLAN
Layer 2 protocol tunneling over Q-in-Q também é suportado
Protocolo de registro de VLAN genérico (GVRP) e Protocolo de registro de atributo genérico (GARP)O Generic VLAN Registration Protocol (GVRP) e o Generic Attribute Registration Protocol (GARP) permitem a propagação automática e a configuração de VLANs em um domínio com ponte
Detecção de link unidirecional (UDLD)O UDLD monitora a conexão física para detectar links unidirecionais causados ​​por fiação incorreta ou falhas de cabo/porta para evitar loops de encaminhamento e bloqueio de tráfego em redes comutadas
Retransmissão do protocolo de configuração de host dinâmico (DHCP) na camada 2Retransmissão de tráfego DHCP para servidor DHCP em VLAN diferente; funciona com opção DHCP 82
Espionagem IGMP (versões 1, 2 e 3)O IGMP limita o tráfego multicast com uso intensivo de largura de banda apenas aos solicitantes; suporta grupos multicast 2K (multicasting específico da fonte também é suportado)
Consultador IGMPO consultador IGMP é usado para suportar um domínio multicast da Camada 2 de switches snooping na ausência de um roteador multicast
bloqueio HOLPrevenção de bloqueio Head-of-Line (HOL)
Detecção de loopbackA detecção de loopback fornece proteção contra loops transmitindo pacotes de protocolo de loop de portas nas quais a proteção de loop foi habilitada. Opera independentemente do STP
Roteamento da camada 3
Roteamento IPv4Roteamento Wire-speed de pacotes IPv4
Até 990 rotas estáticas e até 128 interfaces IP
Roteamento IPv6Roteamento de velocidade de fio de pacotes IPv6
Interface da camada 3Configuração da interface da Camada 3 na porta física, Link Aggregation (LAG), interface VLAN ou interface de loopback
Roteamento entre domínios sem classes (CIDR)Suporte para roteamento entre domínios sem classe
RIP v2Suporte para Routing Information Protocol versão 2 para roteamento dinâmico
Roteamento baseado em políticas (PBR)Controle de roteamento flexível para direcionar pacotes para diferentes próximos saltos com base em lista de controle de acesso (ACL) IPv4 ou IPv6
Servidor DHCPO switch funciona como um servidor DHCP IPv4 servindo endereços IP para vários pools/escopos DHCP
Suporte para opções DHCP
Retransmissão DHCP na camada 3Retransmissão de tráfego DHCP entre domínios IP
User Datagram Protocol (UDP) reléRetransmissão de informações de transmissão em domínios da Camada 3 para descoberta de aplicativos ou retransmissão de pacotes Bootstrap Protocol (BOOTP)/DHCP
Empilhamento
Empilhamento de hardwareAté 4 unidades em uma pilha. Até 192 portas gerenciadas como um único sistema com failover de hardware
Alta disponibilidadeFailover de pilha rápida oferece perda mínima de tráfego. Oferece suporte à agregação de links em várias unidades em uma pilha
Configuração/gerenciamento de empilhamento plug-and-playAtivo/espera para controle resiliente da pilha
Numeração automática
Hot swap de unidades na pilha
Opções de empilhamento de anel e cadeia, velocidade da porta de empilhamento automático, opções flexíveis de porta de empilhamento
Interconexões de pilha de alta velocidadeInterfaces de fibra 10G de alta velocidade econômicas
Segurança
Secure Sockets Layer (SSL)Suporte SSL: criptografa todo o tráfego HTTPS, permitindo acesso altamente seguro à GUI de gerenciamento baseada em navegador no switch
Protocolo Secure Shell (SSH)O SSH é um substituto seguro para o tráfego Telnet. Secure Copy Protocol (SCP) também usa SSH. SSH v1 e v2 são suportados
IEEE 802.1X (função do autenticador)802.1X: Autenticação e contabilidade do Serviço de Usuário de Discagem de Autenticação Remota (RADIUS), hash MD5; VLAN convidada; VLAN não autenticada, modo de host único/múltiplo e sessões únicas/múltiplas
Suporta 802.1X baseado em tempo; atribuição de VLAN dinâmica
Autenticação baseada na WebA autenticação baseada na Web fornece controle de admissão de rede por meio do navegador da Web para qualquer dispositivo host e sistema operacional
STP Bridge Protocol Data Unit (BPDU) GuardUm mecanismo de segurança para proteger a rede de configurações inválidas. Uma porta habilitada para BPDU Guard é desligada se uma mensagem BPDU for recebida nessa porta. Isso evita loops de topologia acidentais
STP Root GuardIsso evita que os dispositivos de borda que não estão sob o controle do administrador da rede se tornem nós raiz do Spanning Tree Protocol
Proteção de loopback STPFornece proteção adicional contra loops de encaminhamento da Camada 2 (loops STP)
Espionagem DHCPFiltra mensagens DHCP com endereços IP não registrados e/ou de interfaces inesperadas ou não confiáveis. Isso evita que dispositivos não autorizados se comportem como servidores DHCP.
IP Source Guard (IPSG)Quando o IP Source Guard está ativado em uma porta, o switch filtra os pacotes IP recebidos da porta se os endereços IP de origem dos pacotes não tiverem sido configurados estaticamente ou aprendidos dinamicamente pela espionagem DHCP. Isso evita a falsificação de endereço IP.
Inspeção ARP Dinâmica (DAI)O switch descarta pacotes ARP de uma porta se não houver vínculos IP/MAC estáticos ou dinâmicos ou se houver uma discrepância entre os endereços de origem ou destino no pacote ARP. Isso evita ataques man-in-the-middle.
IP/MAC/Port Binding (IPMB)Os recursos anteriores (DHCP Snooping, IP Source Guard e Dynamic ARP Inspection) funcionam juntos para evitar ataques DOS na rede, aumentando assim a disponibilidade da rede
Tecnologia Núcleo Segura (SCT)Garante que o switch receberá e processará o gerenciamento e o tráfego de protocolo, independentemente da quantidade de tráfego recebido
Dados confidenciais seguros (SSD)Um mecanismo para gerenciar dados confidenciais (como senhas, chaves e assim por diante) com segurança no switch, preenchendo esses dados para outros dispositivos e autoconfiguração segura. O acesso para visualizar os dados confidenciais como texto simples ou criptografado é fornecido de acordo com o nível de acesso configurado pelo usuário e o método de acesso do usuário.
Sistemas confiáveisSistemas confiáveis ​​fornecem uma base altamente segura para
defesas em tempo de execução dos produtos Cisco (Proteção de espaço executável [X-Space], Randomização de layout de espaço de endereço [ASLR], Verificação de tamanho de objeto integrada [BOSC])
Privado VLANVários níveis de privilégio de usuário na CLIA VLAN privada fornece segurança e isolamento entre as portas do switch, o que ajuda a garantir que os usuários não possam bisbilhotar o tráfego de outros usuários; suporta vários uplinks
Isolamento de camada 2 Private VLAN Edge (PVE) com comunidade VLANPVE (também conhecido como portas protegidas) fornece isolamento de Camada 2 entre dispositivos na mesma VLAN, suporta vários uplinks
segurança portuáriaCapacidade de bloquear endereços MAC de origem em portas e limitar o número de endereços MAC aprendidos
RAIO/TACACS+Suporta autenticação RADIUS e TACACS. Alternar funções como cliente
contabilidade RADIUSAs funções de contabilização RADIUS permitem o envio de dados no início e no fim dos serviços, indicando a quantidade de recursos (como tempo, pacotes, bytes, etc.) utilizados durante a sessão
controle de tempestadeBroadcast, multicast e unicast desconhecido
Prevenção DoSPrevenção de ataques de negação de serviço (DOS)
Múltiplos níveis de privilégio de usuário na CLINíveis de privilégio de nível 1, 7 e 15
ACLsSuporte para até 1.024 regras
Drop ou limite de taxa com base no MAC de origem e destino, VLAN ID, endereço IPv4 ou IPv6, rótulo de fluxo IPv6, protocolo, porta, ponto de código de serviços diferenciados (DSCP)/precedência de IP, protocolo de controle de transmissão/datagrama do usuário Portas de origem e destino do protocolo (TCP/UDP), prioridade 802.1p, tipo Ethernet, pacotes ICMP (Internet Control Message Protocol), pacotes IGMP, sinalizador TCP; ACL pode ser aplicada nos lados de entrada e saída
ACLs baseados em tempo suportados
Qualidade de serviço
Níveis de prioridade8 filas de hardware
AgendamentoPrioridade estrita e Round-Robin ponderado (WRR)
classe de serviçoBaseado em porto; baseado em prioridade de VLAN 802.1p; Precedência de IP IPv4/v6/Tipo de serviço (ToS)/baseado em DSCP; Serviços Diferenciados (DiffServ);
ACLs de classificação e observação, atribuição de fila de QoS confiável com base em DSCP e classe de serviço (802.1p/CoS)
Limitação de taxaPolicial de ingresso; modelagem de saída e controle de taxa; por VLAN, por porta e com base em fluxo; policiamento 2R3C
prevenção de congestionamentoUm algoritmo de prevenção de congestionamento TCP é necessário para minimizar e evitar a sincronização global de perda de TCP
Otimização de tráfego iSCSIUm mecanismo para dar prioridade ao tráfego iSCSI sobre outros tipos de tráfego
Padrões
PadrõesIEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3ad Link Aggregation Control Protocol, IEEE 802.3z Gigabit Ethernet, IEEE 802.3ae 10 Gbit/s Ethernet sobre fibra para LAN, IEEE 802.3an 10GBase-T 10 Gbit/s Ethernet sobre cabo de par trançado de cobre, IEEE 802.3x Flow Control, IEEE 802.1D (STP, GARP e GVRP), IEEE 802.1Q/p VLAN, IEEE 802.1w Rapid STP, IEEE 802.1s Multiple STP, IEEE 802.1X Port Access Authentication, IEEE 802.3af, IEEE 802.3at, IEEE 802.1AB Link Layer Discovery Protocol, IEEE 802.3az Energy Efficient Ethernet, RFC 768, RFC 783, RFC 791, RFC 792, RFC 793 , RFC 813, RFC 826, RFC 879, RFC 896, RFC 854, RFC 855, RFC 856, RFC 858, RFC 894, RFC 919, RFC 920, RFC 922, RFC 950, RFC 951, RFC 1042, RFC 1071, RFC 1123, RFC 1141, RFC 1155, RFC 1157, RFC 1213, RFC 1215, RFC 1286,RFC 1350, RFC 1442, RFC 1451, RFC 1493, RFC 1533, RFC 1541, RFC 1542, RFC 1573, RFC 1624, RFC 1643, RFC 1700, RFC 1757, RFC 1867, RFC 1907, RFC 2011, RFC 2011, RFC 2012 , RFC 2030, RFC 2131, RFC 2132, RFC 2233, RFC 2576, RFC 2616, RFC 2618, RFC 2665, RFC 2666, RFC 2674, RFC 2737, RFC 2819, RFC 2863, RFC 3164, RFC 3176, RFC 3141 3412, RFC 3413, RFC 3414, RFC 3415, RFC 3416, RFC 4330
IPv6
IPv6modo de host IPv6; IPv6 sobre Ethernet; Pilha dupla IPv6/IPv4
vizinho IPv6 e descoberta de roteador (ND); Autoconfiguração de endereços IPv6 sem estado; Path Maximum Transmission Unit (MTU) descoberta
Detecção de Endereço Duplicado (DAD); ICMP versão 6
DHCPv6 stateful client
IPv6 sobre rede IPv4 com suporte ao Intrasite Automatic Tunnel Addressing Protocol (ISATAP)
certificado USGv6 e IPv6 Gold Logo
IPv6 QoSPriorizar pacotes IPv6 no hardware
IPv6 ACLEliminar ou limitar a taxa de pacotes IPv6 no hardware
Segurança de primeiro salto IPv6Proteção RA
ND Inspeção
Proteção DHCPv6
Tabela de ligação de vizinho (entradas de espionagem e estáticas)
Verificação de integridade de ligação de vizinho
Espionagem de descoberta de ouvinte multicast (MLD v1/2)Entregue pacotes multicast IPv6 apenas para os receptores necessários
aplicações IPv6Web/SSL, servidor Telnet/SSH, ping, traceroute, Simple Network Time Protocol (SNTP), Trivial File Transfer Protocol (TFTP), SNMP, RADIUS, syslog, cliente DNS (Domain Name System), cliente Telnet, cliente DHCP, DHCP Autoconfig, IPv6 DHCP Relay, Terminal Access Controller Access Control System Plus (TACACS+)
RFCs IPv6 suportadosRFC 4443 (que torna obsoleto o RFC 2463): ICMPv6
RFC 4291 (que torna obsoleto o RFC 3513): Arquitetura de endereço IPv6
RFC 4291: Arquitetura de endereçamento IPv6
RFC 2460: Especificação IPv6
RFC 4861 (que torna obsoleto o RFC 2461): Neighbor Discovery for IPv6 RFC 4862 (que torna obsoleto o
RFC 2461): obsoleto RFC 2462): IPv6 Stateless Address Autoconfiguration
RFC 1981: Path MTU Discovery
RFC 4007: IPv6 Scoped Address Architecture
RFC 3484: Default address selection engine
RFC 5214 (que torna obsoleto RFC 4214): ISATAP tunneling
RFC 4293: Management Information Base (MIB) IPv6 : Convenções Textuais e Grupo Geral
RFC 3595: Convenções textuais para rótulo de fluxo IPv6
Gerenciamento
Painel de negócios da CiscoSuporte para sonda incorporada para Cisco Business Dashboard em execução no switch. Elimina a necessidade de configurar um hardware separado ou uma máquina virtual para o Cisco Business Dashboard Probe no local.
Aplicativo móvel Cisco BusinessAplicativo móvel para produtos Cisco Business Switch e Wireless. Ajuda a configurar uma rede local em minutos e fornece gerenciamento fácil ao seu alcance.
Agente Cisco Network Plug and Play (PnP)A solução Cisco Network Plug and Play oferece uma oferta simples, segura, unificada e integrada para facilitar a implantação de novos dispositivos em filiais ou campus ou para provisionar atualizações para uma rede existente. A solução fornece uma abordagem unificada para fornecer roteadores, switches e dispositivos sem fio Cisco com uma experiência de implantação quase sem toque.
Suporta Cisco PnP Connect
interface do usuário da webUtilitário de configuração de switch integrado para fácil configuração de dispositivo baseada em navegador (HTTP/HTTPS). Suporta configuração, assistentes, painel do sistema, manutenção do sistema e monitoramento
Modo básico e avançado para máxima eficiência operacional
SNMPSNMP versões 1, 2c e 3 com suporte para traps e SNMP v3 User-based Security Model (USM)
MIBs padrãolldp-MIB
lldpextdot1-MIB
lldpextdot3-MIB
lldpextmed-MIB
rfc2674-MIB
rfc2575-MIB
rfc2573-MIB
rfc2233-MIB
rfc2013-MIB
rfc2012-MIB
rfc2011-MIB
RFC-1212
RFC-1215
SNMPv2-CONF
SNMPv2-TC
p-bridge-MIB
q-bridge-MIB
rfc1389-MIB
rfc1493-MIB
rfc1611-MIB
rfc1612-MIB
rfc1850-MIB
rfc1907-MIB
rfc2571-MIB
rfc2572-MIB
rfc2574-MIB
rfc2576-MIB
rfc2613-MIB
rfc2665-MIB
rfc2668-MIB
rfc2737-MIB
rfc2925-MIB
rfc3621-MIB
rfc4668-MIB
rfc4670-MIB
tronco-MIB
túnel-MIB
udp-MIB
draft-ietf-bridge-8021x-MIB
draft-ietf-bridge-rstpmib-04-MIB
draft-ietf -hubmib-etherif-mib-v3-00-MIB
draft-ietf-syslog-device-MIB
ianaaddrfamnumbers-MIB
ianaifty-MIB
ianaprot-MIB
inet-address-MIB
ip-forward-MIB
ip-MIB
RFC1155-SMI
RFC1213-MIB
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TM
RMON-MIB
rfc1724-MIB
dcb-raj-DCBX-MIB-1108-MIB
rfc1213-MIB
rfc1757-MIB
MIBs privadosCISCOSB-lldp-MIB
CISCOSB-brgmulticast-MIB
CISCOSB-bridgemibobjects-MIB
CISCOSB-bonjour-MIB
CISCOSB-dhcpcl-MIB CISCOSB
-MIB
CISCOSB-wrandomtaildrop-MIB
CISCOSB-traceroute-MIB
CISCOSB-telnet-MIB
CISCOSB-stormctrl-MIB
CISCOSBssh- MIB
CISCOSB-socket-MIB
CISCOSB-sntp-MIB
CISCOSB-smon-MIB
CISCOSB-phy-MIB
CISCOSB-multisessionterminal-MIB
CISCOSB-mri-MIB
CISCOSB-jumboframes-MIB CISCOSB-
gvrp-MIB
CISCOSB-endofmib-MIB
CISCOSB-dot1x-MIB
CISCOSB-deviceparams-MIB
CISCOSB-cli-MIB
CISCOSB-cdb-MIB
CISCOSB-brgmacswitch-MIB
CISCOSB-3sw2swtables-MIB
CISCOSB-smartPorts-MIB
CISCOSB-tbi-MIB
CISCOSB-macbaseprio-MIB
CISCOSB-env_mib-MIB
CISCOSB-policy-MIB
CISCOSB-sensor-MIB
CISCOSB-aaa-MIB
CISCOSB-application-MIB
CISCOSB-bridgesecurity-MIB
CISCOSB-copy-MIB
CISCOSB-CpuCounters-MIB
CISCOSB-Custom1BonjourService-MIB
CISCOSB-dhcp-MIB
CISCOSB-dlf-MIB
CISCOSB-dnscl-MIB
CISCOSB-embweb-MIB
CISCOSB-fft-MIB
CISCOSB-file-MIB
CISCOSB-greeneth-MIB
CISCOSB-interfaces-MIB
CISCOSB-interfaces_recovery-MIB
CISCOSB-ip-MIB
CISCOSB-iprouter-MIB
CISCOSB-ipv6-MIB
CISCOSB-mnginf-MIB
CISCOSB-lcli-MIB
CISCOSB-localização-MIB
CISCOSB-mcmngr-MIB
CISCOSB-mng-MIB
CISCOSB-fisdescrição-MIB
CISCOSB-PoE-MIB
CISCOSB-protectedport-MIB
CISCOSB-rmon-MIB
CISCOSB-rs232-MIB
CISCOSB-SecuritySuite-MIB
CISCOSB-snmp-MIB
CISCOSB-specialbpdu-MIB CISCOSB
-banner-MIB CISCOSB-
syslog-MIB
CISCOSB-TcpSession-MIB
CISCOSB-traps-MIB
CISCOSB-trunk-MIB
CISCOSB-tuning-MIB
CISCOSB-tunnel-MIB
CISCOSB-udp-MIB
CISCOSB-vlan-MIB CISCOSB
-ipstdacl-MIB
CISCOSB-eee-MIB
CISCOSB-ssl-MIB
CISCOSB-qosclimib-MIB
CISCOSB-digitalkeymanage-MIB
CISCOSB-tbp-MIB
CISCOSMB-MIB
CISCOSB-secsd-MIB
CISCOSB-draft-ietf-entmib-sensor-MIB
CISCOSB-draft-ietf-syslog-device-MIB
CISCOSB-rfc2925-MIB
CISCO-SMI-MIB
CISCOSB-DebugCapabilities-MIB
CISCOSB-CDP-MIB
CISCOSB-vlanVoice-MIB
CISCOSB-EVENTS-MIB
CISCOSB-sysmng-MIB CISCOSB
-sct-MIB CISCO
-TC-MIB CISCO-
VTP-MIB
CISCO-CDP-MIB
Monitoramento remoto (RMON)O agente de software RMON incorporado suporta 4 grupos RMON (histórico, estatísticas, alarmes e eventos) para gerenciamento, monitoramento e análise de tráfego aprimorados
Pilha dupla IPv4 e IPv6Coexistência de ambas as pilhas de protocolo para facilitar a migração
Atualização de firmwareAtualização do navegador da Web (HTTP/HTTPS) e TFTP e atualização sobre SCP executando sobre SSH
Imagens duplas para atualizações de firmware resilientes
Espelhamento de portaO tráfego em uma porta pode ser espelhado em outra porta para análise com um analisador de rede ou sonda RMON. Até 4 portas de origem podem ser espelhadas em uma porta de destino
Espelhamento de VLANO tráfego de uma VLAN pode ser espelhado em uma porta para análise com um analisador de rede ou sonda RMON. Até 4 VLANs de origem podem ser espelhadas em uma porta de destino
Dynamic Host Configuration Protocol (DHCP) (opções 12, 66, 67, 129 e 150)As opções de DHCP facilitam um controle mais rígido a partir de um ponto central (servidor DHCP), para obter endereço IP, autoconfiguração (com download do arquivo de configuração), DHCP Relay e nome do host
Cópia Segura (SCP)Transfere arquivos com segurança de e para o switch
Autoconfiguração com download de arquivo SCPPermite implantação em massa com proteção de dados confidenciais
Configurações editáveis ​​em textoOs arquivos de configuração podem ser editados com um editor de texto e baixados para outro switch, facilitando a implantação em massa
SmartportsConfiguração simplificada de QoS e recursos de segurança
Auto SmartportsAplica automaticamente a inteligência fornecida por meio das funções Smartports à porta com base nos dispositivos descobertos por meio do Cisco Discovery Protocol ou LLDP-MED. Isso facilita implantações sem intervenção.
Visualização de texto Interface de linha de comando (CLI)CLI programável. Uma CLI completa, bem como uma CLI baseada em menu, são suportadas. Os níveis de privilégio de usuário 1, 7 e 15 são compatíveis com a CLI.
LocalizaçãoLocalização de GUI e documentação em vários idiomas
banner de loginMúltiplos banners configuráveis ​​para web, bem como CLI
outra gestãoTraceroute; gerenciamento de IP único; HTTP/HTTPS; RAIO; espelhamento de porta; Atualização de TFTP; cliente DHCP; Protocolo Simples de Tempo de Rede (SNTP); diagnóstico de cabos; Ping; log do sistema; Cliente Telnet (suporte seguro SSH); configurações automáticas de tempo da estação de gerenciamento
Verde (Eficiência de Energia)
Detecção de energiaDesliga automaticamente a energia na porta RJ-45 ao detectar link inativo. O modo ativo é retomado sem perda de nenhum pacote quando o switch detecta que o link está ativo
Detecção de comprimento de caboAjusta a intensidade do sinal com base no comprimento do cabo. Reduz o consumo de energia para cabos mais curtos
Compatível com EEE (802.3az)Suporta IEEE 802.3az em todas as portas Gigabit Ethernet de cobre
Desativar LEDs de portaOs LEDs podem ser desligados manualmente para economizar energia
Operação de porta baseada em tempoLink para cima ou para baixo com base na programação definida pelo usuário (quando a porta estiver administrativamente ativa)
PoE baseado em tempoA energia PoE pode ser ligada ou desligada com base na programação definida pelo usuário para economizar energia
Em geral
Quadros jumboTamanhos de quadro de até 9K bytes. O MTU padrão é 2K bytes
tabela MAC16K endereços
Descoberta
Bom diaO switch se anuncia usando o protocolo Bonjour
Link Layer Discovery Protocol (LLDP) (802.1ab) com extensões LLDP-MEDO Link Layer Discovery Protocol (LLDP) permite que o switch anuncie sua identificação, configuração e recursos para dispositivos vizinhos que armazenam os dados em um MIB. LLDP-MED é um aprimoramento do LLDP que adiciona as extensões necessárias para telefones IP
Protocolo de Descoberta CiscoO switch se anuncia usando o Cisco Discovery Protocol. Também aprende o dispositivo conectado e suas características usando o Cisco Discovery Protocol
Power over Ethernet (PoE)
802.3af PoE, 802.3at PoE+ ou 60W PoE fornecido pelas portas RJ-45 dentro dos orçamentos de energia listadosOs seguintes switches suportam 802.3at PoE+, 802.3af e Cisco pré-padrão (legado) PoE. O PoE de 60 W também é suportado em portas de rede RJ-45 selecionadas em modelos selecionados. A potência total disponível para PoE por switch é a seguinte:
ModeloEnergia dedicada ao PoENúmero de portas que suportam PoE
CBS350-8P-2G67 W8
CBS350-8P-E-2G60W8
CBS350-8FP-2G120W8
CBS350-8FP-E-2G120W8
CBS350-16P-2G120W16
CBS350-16P-E-2G120W16
CBS350-16FP-2G120W16
350-24P-4G240W24
CBS350-24FP-4G195W24
350-48P-4G370 W48
CBS350-48FP-4G370 W48
Consumo de energia (pior caso)ModeloConsumo de energia do sistemaConsumo de energia (com PoE)Dissipação de calor (BTU/h)
350-8T-E-2G110V=12,55W
220V=12,56W
N / D42,86
350-8P-2G110V=17,35W
220V=17,95W
110V=83,17W
220V=82,63W
283,79
350-8P-E-2G110V=13,84W
220V=14,31W
110V=80,79W
220V=80,86W
275,91
350-8FP-2G110V=17,29W
220V=17,88W
110V=148,12W
220V=146,36W
505.41
350-8FP-E-2G110V=17,07W
220V=16,68W
110V=147,48W
220V=145,26W
503.22
350-8S-E-2G110V=11,1W
220V=11,9W
N / D40,6
350-16T-2G110V=18,63W
220V=18,37W
N / D64,46
350-16T-E-2G110V=19,63W
220V=19,32W
N / D65,92
350-16P-2G110V=24,51W
220V=25,01W
110V=156,4W
220V=154,5W
536,39
350-16P-E-2G110V=23,65W
220V=23,68W
110V=150,1W
220V=148,8W
512.16
350-16FP-2G110V=27,53W
220V=26,68W
110V=284W
220V=279,8W
971,78
350-24T-4G110V=25,91W
220V=25,63W
N / D89.13
350-24P-4G110V=34,42W
220V=33,09W
110V=239,7W
220V=236,4W
820,62
350-24FP-4G110V=46,60W
220V=46,35W
110V=449,7W
220V=438,3W
1.537,17
350-24S-4G110V=32,0W
220V=34,3W
N / D117,0
350-48T-4G110V=48,27W
220V=48,64W
N / D165,96
350-48P-4G110V=60,77W
220V=59,73W
110V=451,95W
220V=445,85W
1.542,12
350-48FP-4G110V=73,79W
220V=74,03W
110V=886,42W
220V=859,50W
3.024,59
portasNome do modeloTotal de portas do sistemaportas RJ-45Portas combinadas (RJ-45 + SFP)
CBS350-8T-E-2G10 x Gigabit Ethernet8 x Gigabit Ethernet2 x Combinação Gigabit Ethernet
CBS350-8P-2G10 x Gigabit Ethernet8 x Gigabit Ethernet2 x Combinação Gigabit Ethernet
CBS350-8P-E-2G10 x Gigabit Ethernet8 x Gigabit Ethernet2 x Combinação Gigabit Ethernet
CBS350-8FP-2G10 x Gigabit Ethernet8 x Gigabit Ethernet2 x Combinação Gigabit Ethernet
CBS350-8FP-E-2G10 x Gigabit Ethernet8 x Gigabit Ethernet2 x Combinação Gigabit Ethernet
CBS350-8S-E-2G10 x Gigabit Ethernet8 Slots Gigabit SFP2 x Combinação Gigabit Ethernet
CBS350-16T-2G18 x Gigabit Ethernet16 x Gigabit Ethernet2x SFP
CBS350-16T-E-2G18 x Gigabit Ethernet16 x Gigabit Ethernet2x SFP
CBS350-16P-2G18 x Gigabit Ethernet16 x Gigabit Ethernet2x SFP
CBS350-16P-E-2G18 x Gigabit Ethernet16 x Gigabit Ethernet2x SFP
CBS350-16FP-2G18 x Gigabit Ethernet16 x Gigabit Ethernet2x SFP
CBS350-24T-4G28 x Gigabit Ethernet24 x Gigabit Ethernet4 x SFP
CBS350-24P-4G28 x Gigabit Ethernet24 x Gigabit Ethernet4 x SFP
CBS350-24FP-4G28 x Gigabit Ethernet24 x Gigabit Ethernet4 x SFP
CBS350-24S-4G28 x Gigabit Ethernet24 Slots Gigabit SFP4 x SFP
CBS350-48T-4G52 x Gigabit Ethernet48 x Gigabit Ethernet4 x SFP
CBS350-48P-4G52 x Gigabit Ethernet48 x Gigabit Ethernet4 x SFP
CBS350-48FP-4G52 x Gigabit Ethernet48 x Gigabit Ethernet4 x SFP
Porta do consolePorta de console mini USB tipo B/RJ45 padrão da Cisco: CBS350-8T-E-2G, CBS350-8P-2G, CBS350-8P-E-2G, CBS350-8FP-2G, CBS350-8FP-E-2G, CBS350- 16T-2G, CBS350-16T-E-2G, CBS350-16P-2G, CBS350-16P-E-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G
Porta de console RJ45 padrão Cisco: CBS350-8S-E-2G, CBS350-24S-4G
entrada USBSlot USB tipo A no painel frontal do switch para fácil gerenciamento de arquivos e imagens
BotõesBotão de reset
Tipo de cabeamentoPar trançado não blindado (UTP) Categoria 5e ou melhor para 1000BASE-T
LEDsSistema, Link/Act, PoE, Velocidade
Clarão256 MB
CPU800 MHz ARM
DRAM512 MB
buffer de pacotesTodos os números são agregados em todas as portas porque os buffers são compartilhados dinamicamente:
Nome do modelobuffer de pacotes
CBS350-8T-E-2G1,5 MB
CBS350-8P-2G1,5 MB
CBS350-8P-E-2G1,5 MB
CBS350-8FP-2G1,5 MB
CBS350-8FP-E-2G1,5 MB
CBS350-8S-E-2G1,5 MB
CBS350-16T-2G1,5 MB
CBS350-16T-E-2G1,5 MB
CBS350-16P-2G1,5 MB
CBS350-16P-E-2G1,5 MB
CBS350-16FP-2G1,5 MB
CBS350-24T-4G1,5 MB
CBS350-24P-4G1,5 MB
CBS350-24FP-4G1,5 MB
CBS350-24S-4G1,5 MB
CBS350-48T-4G3 MB
CBS350-48P-4G3 MB
CBS350-48FP-4G3 MB
Módulos SFP/SFP+ suportadosSKUmeios de comunicaçãoVelocidadeDistância máxima
MGBSX1fibra multimodo1000 Mbps500m
MGBLH1Fibra monomodo1000 Mbps40 km
MGBLX1Fibra monomodo1000 Mbps10 km
MGBT1UTP cat 5e1000 Mbps100m
GLC-SX-MMDfibra multimodo1000 Mbps550 m
GLC-LH-SMDFibra monomodo1000 Mbps10 km
GLC-BX-UFibra monomodo1000 Mbps10 km
GLC-BX-DFibra monomodo1000 Mbps10 km
GLC-TEUTP cat 5e1000 Mbps100m
SFP-H10GB-CU1Mcobre coaxial10 GB1m
SFP-H10GB-CU3Mcobre coaxial10 GB3m
SFP-H10GB-CU5Mcobre coaxial10 GB5m
SFP-10G-SRfibra multimodo10 GB26 m – 400 m
SFP-10G-LRFibra monomodo10 GB10 km
SFP-10G-SR-Sfibra multimodo10 GB26 m – 400 m
SFP-10G-LR-SFibra monomodo10 GB10 km
Ambiental
Dimensões da unidade
(L x P x A)
Nome do modeloDimensões da unidade
CBS350-8T-E-2G268 x 185 x 44 mm (10,56 x 7,28 x 1,73 pol.)
CBS350-8P-2G268 x 272 x 44 mm (10,56 x 10,71 x 1,73 pol.)
CBS350-8P-E-2G268 x 185 x 44 mm (10,56 x 7,28 x 1,73 pol.)
CBS350-8FP-2G268 x 272 x 44 mm (10,56 x 10,71 x 1,73 pol.)
CBS350-8FP-E-2G268 x 185 x 44 mm (10,56 x 7,28 x 1,73 pol.)
CBS350-8S-E-2G280 x 170 x 44 mm (11,0 x 6,69 x 1,73 pol.)
CBS350-16T-2G268 x 272 x 44 mm (10,56 x 10,69 x 1,73 pol.)
CBS350-16T-E-2G268 x 210 x 44 mm (10,56 x 8,26 x 1,73 pol.)
CBS350-16P-2G268 x 297 x 44 mm (10,56 x 11,69 x 1,73 pol.)
CBS350-16P-E-2G268 x 210 x 44 mm (10,56 x 8,26 x 1,73 pol.)
CBS350-16FP-2G268 x 308 x 44 mm (10,56 x 12,14 x 1,73 pol.)
CBS350-24T-4G445 x 240 x 44 mm (17,5 x 9,45 x 1,73 pol.)
CBS350-24P-4G445 x 299 x 44 mm (17,5 x 11,77 x 1,73 pol.)
CBS350-24FP-4G445 x 345 x 44 mm (17,5 x 13,59 x 1,73 pol.)
CBS350-24S-4G440 x 203 x 44 mm (17,3 x 7,99 x 1,73 pol.)
CBS350-48T-4G445 x 288 x 44 mm (17,5 x 11,33 x 1,73 pol.)
CBS350-48P-4G445 x 350 x 44 mm (17,5 x 13,78 x 1,73 pol.)
CBS350-48FP-4G445 x 350 x 44 mm (17,5 x 13,78 x 1,73 pol.)
Unidade de pesoNome do modeloUnidade de peso
CBS350-8T-E-2G1,39 kg (3,06 libras)
CBS350-8P-2G2,59 kg (5,71 lb)
CBS350-8P-E-2G1,53 kg (3,37 lb)
CBS350-8FP-2G2,59 kg (5,71 lb)
CBS350-8FP-E-2G1,53 kg (3,37 lb)
CBS350-8S-E-2G1,0 kg (2,20 lb)
CBS350-16T-2G1,78 kg (3,92 libras)
CBS350-16T-E-2G1,42 kg (3,13 libras)
CBS350-16P-2G2,38 kg (5,25 lb)
CBS350-16P-E-2G1,42 kg (3,13 libras)
CBS350-16FP-2G2,49 kg (5,49 lb)
CBS350-24T-4G2,63 kg (5,80 lb)
CBS350-24P-4G3,53 kg (7,78 lb)
CBS350-24FP-4G4,6 kg (10,14 libras)
CBS350-24S-4G2,7 kg (5,95 libras)
CBS350-48T-4G3,95 kg (8,71 libras)
CBS350-48P-4G5,43 kg (11,97 libras)
CBS350-48FP-4G5,82 kg (12,83 libras)
Poder100-240 V 50-60 Hz, interno, universal: CBS350-8P-2G, CBS350-8FP-2G, CBS350-16T-2G, CBS350-16P-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350- 24P-4G, CBS350-24FP-4G, CBS350-24S-4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G
100-240V 50-60 Hz, externo: CBS350-8T-E-2G , CBS350-8P-E-2G, CBS350-8FP-E-2G, CBS350-8S-E-2G, CBS350-16T-E-2G, CBS350-16P-E-2G
CertificaçãoUL (UL 60950), CSA (CSA 22.2), marca CE, FCC Parte 15 (CFR 47) Classe A
Temperatura de operação23° a 122°F (-5° a 50°C)
CBS350-8T-E-2G, CBS350-8P-2G, CBS350-8P-E-2G, CBS350-8FP-2G, CBS350-8FP-E-2G , CBS350-16T-2G, CBS350-16T-E-2G, CBS350-16P-2G, CBS350-16P-E-2G, CBS350-16FP-2G, CBS350-24T-4G, CBS350-24P-4G, CBS350-24FP -4G, CBS350-48T-4G, CBS350-48P-4G, CBS350-48FP-4G
32° a 122°F (0° a 50°C)
CBS350-8S-E-2G, CBS350-24S-4G
Temperatura de armazenamento-13° a 158°F (-25° a 70°C)
Umidade operacional10% a 90%, relativo, sem condensação
Umidade de armazenamento10% a 90%, relativo, sem condensação
Ruído acústico e tempo médio entre falhas (MTBF)Nome do modelo CBSVentilador (número)ruído acústicoMTBF a 25°C (horas)
350-8T-E-2Gsem ventoinhaN / D2.171.669
350-8P-2Gsem ventoinhaN / D1.786.412
350-8P-E-2Gsem ventoinhaN / D1.706.649
350-8FP-2Gsem ventoinhaN / D1.786.412
350-8FP-E-2Gsem ventoinhaN / D1.706.649
350-8S-E-2Gsem ventoinhaN / D2.242.229
350-16T-2Gsem ventoinhaN / D2.165.105
350-16T-E-2Gsem ventoinhaN / D2.165.105
350-16P-2Gsem ventoinhaN / D706.983
350-16P-E-2Gsem ventoinhaN / D706.983
350-16FP-2Gsem ventoinhaN / D706.983
350-24T-4Gsem ventoinhaN / D2.026.793
350-24P-4Gsem ventoinhaN / D698.220
350-24FP-4G125°C: 34,8 dBA698.220
350-24S-4Gsem ventoinhaN / D258.544
350-48T-4G125°C: 29,7 dBA1.452.667
350-48P-4G125°C: 37,3 dBA856.329
350-48FP-4G125°C: 48,7 dBA856.301
garantia

Tempo de vida limitado

 

Conteúdo do pacote
  • Interruptor Inteligente Cisco Business 350 Series
  • Cabo de alimentação (adaptador de alimentação para SKUs selecionados de 8 e 16 portas)
  • Kit de montagem
  • Guia rápido

 

Requerimentos mínimos
  • Navegador da Web: Chrome, Firefox, Edge, Safari
  • Cabo de rede Ethernet categoria 5e
  • TCP/IP, adaptador de rede e sistema operacional de rede (como Microsoft Windows, Linux ou Mac OS X) instalado

 . .